kW to amps Bangla
Convert kW to amps for the Bangladesh 230 V single-phase or 400 V three-phase supply and compare the current with common household loads.
Inputs
Current of common household loads
How kW to amps Bangla calculator works
The kW to amps Bangla calculator converts kilowatts (kW) into amperes (A) on the Bangladesh 230 V single-phase or 400 V three-phase supply with 3 inputs: power, voltage and power factor. The calculator returns the current, the apparent power in kilovolt-amperes (kVA) and a breaker size, and the lollipop chart compares the current with 7 common household loads.
I = P × 1000 / (V × PF)1 kW at 230 V and PF 0.9 draws 4.83 A, the same current as an electric iron. A 1.5 ton air conditioner (AC) with 1.6 kW input draws 7.73 A at 230 V.
kW to amps Bangla formula
The kW to amps Bangla formula is I(A) = P(kW) × 1,000 / (V × PF) for single phase. There are 3 formulas for Bangladesh supplies: 230 V single phase, 400 V three phase and breaker sizing.
230 V single phase
I = P × 1000 / (230 × PF)1 kW × 1,000 / (230 V × 0.9) = 4.83 A
400 V three phase
I = P × 1000 / (√3 × 400 × PF)10 kW × 1,000 / (1.732 × 400 V × 0.9) = 16.04 A
Breaker sizing
Breaker ≥ 1.25 × I1.25 × 13.04 A = 16.3 A → 20 A breaker
Homes in Bangladesh receive 230 V single phase at 50 hertz (Hz), and factories receive 400 V three phase. Older meters and appliances list 220 V, which raises the current by 4.5% for the same kW.
kW to amps Bangla conversion chart
The kW to amps Bangla conversion chart lists 11 loads from 0.1 kW to 10 kW at 220 V, 230 V and 400 V, with a 230 V column at power factor 0.8 for fans, pumps and air conditioners.
| kW | 220 VPF 1 | 230 VPF 1 | 230 VPF 0.8 | 400 V 3φPF 1 |
|---|---|---|---|---|
| 0.1 kW | 0.45 | 0.43 | 0.54 | 0.14 |
| 0.25 kW | 1.14 | 1.09 | 1.36 | 0.36 |
| 0.5 kW | 2.27 | 2.17 | 2.72 | 0.72 |
| 0.75 kW | 3.41 | 3.26 | 4.08 | 1.08 |
| 1 kW | 4.55 | 4.35 | 5.43 | 1.44 |
| 1.5 kW | 6.82 | 6.52 | 8.15 | 2.17 |
| 2 kW | 9.09 | 8.7 | 10.87 | 2.89 |
| 3 kW | 13.64 | 13.04 | 16.3 | 4.33 |
| 5 kW | 22.73 | 21.74 | 27.17 | 7.22 |
| 7.5 kW | 34.09 | 32.61 | 40.76 | 10.83 |
| 10 kW | 45.45 | 43.48 | 54.35 | 14.43 |
A 0.75 kW (1 horsepower, hp) water pump draws 4.08 A at 230 V and PF 0.8.
kW to amps Bangla Excel formula
The kW to amps Bangla Excel formula is =A2*1000/(B2*C2) with kW in A2, volts in B2 and power factor in C2. Use =A2*1000/(SQRT(3)*B2*C2) for 400 V three-phase loads.
| A | B | C | D | E | |
|---|---|---|---|---|---|
| 1 | kW | Volts | PF | Amps | Formula in D |
| 2 | 1 | 230 | 0.9 | 4.83 | =ROUND(A2*1000/(B2*C2),2) |
| 3 | 1.6 | 230 | 0.9 | 7.73 | =ROUND(A3*1000/(B3*C3),2) |
| 4 | 10 | 400 | 0.9 | 16.04 | =ROUND(A4*1000/(SQRT(3)*B4*C4),2) |
Row 3 is a 1.5 ton air conditioner. Add =D2*1.25 in column E to get the minimum breaker rating.
kW to amps Bangla equation
The kW to amps Bangla equation is I = P × 1,000 / (V × PF), written in Bangla as অ্যাম্পিয়ার = কিলোওয়াট × ১০০০ ÷ (ভোল্ট × পাওয়ার ফ্যাক্টর).
- I
- Current, অ্যাম্পিয়ার (A)
- P
- Power, কিলোওয়াট (kW)
- V
- Voltage, ভোল্ট (V)
- PF
- Power factor, পাওয়ার ফ্যাক্টর
Each kW on a 230 V circuit adds 4.35 A at PF 1, and each kW at 220 V adds 4.55 A.
kW to amps Bangla FAQ
How many amps is 1 kW in Bangladesh?
1 kW is 4.35 A at 230 V and 4.55 A at 220 V, at a power factor of 1. At PF 0.8 the same 1 kW draws 5.43 A at 230 V.
How many amps does a 1.5 ton AC draw in Bangladesh?
A 1.5 ton AC draws about 7.73 A at 230 V, for an input power of 1.6 kW and a power factor of 0.9. An inverter AC draws less current at part load.
What breaker size for 3 kW in Bangladesh?
3 kW needs a 20 A breaker at 230 V: 3 kW draws 13.04 A, and 125% of that current is 16.3 A.
কিলোওয়াট থেকে অ্যাম্পিয়ার কীভাবে বের করবেন?
অ্যাম্পিয়ার = কিলোওয়াট × ১০০০ ÷ (ভোল্ট × পাওয়ার ফ্যাক্টর)। ২৩০ ভোল্টে ১ কিলোওয়াট লোড প্রায় ৪.৩৫ অ্যাম্পিয়ার কারেন্ট টানে।
কিলোওয়াট থেকে অ্যাম্পিয়ার (বাংলা)
সিঙ্গেল ফেজ: অ্যাম্পিয়ার = কিলোওয়াট × ১০০০ ÷ (ভোল্ট × পাওয়ার ফ্যাক্টর)।
থ্রি ফেজ: অ্যাম্পিয়ার = কিলোওয়াট × ১০০০ ÷ (√৩ × ভোল্ট × পাওয়ার ফ্যাক্টর)।
উদাহরণ: ১ কিলোওয়াট লোড, ২৩০ ভোল্ট এবং পাওয়ার ফ্যাক্টর ০.৯ হলে কারেন্ট প্রায় ৪.৮৩ অ্যাম্পিয়ার।
বাংলাদেশে বাসাবাড়িতে ২৩০ ভোল্ট সিঙ্গেল ফেজ এবং কলকারখানায় ৪০০ ভোল্ট থ্রি ফেজ বিদ্যুৎ সরবরাহ করা হয়।